En mi búsqueda del conocimiento por la red y mis ganas de optimizar más la plataforma de monitorización, encontré este documento de gran utilidad repletos de variables y parámetros que podemos incluir ( siempre con cabeza ) en el fichero ovconfchg y nos ayudará a filtrar y organizar mejor los agentes en los servidores. CA_ANNO_NODE Flags : external Description : Setup add.l ECS annotate nodes on OVO managed nodes. See ECS 3.1 manual "Configuring Circuits for NNM and OVO". Type/Unit : string Default : "" Documented : See ECS 3.1 manual "Configuring Circuits for NNM and OVO". Since Rel. : A.07.00 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : ECS ECA_INSTANCE Flags : external Description : Instance-number of OVO's ECS engine on managed node (opceca). OVO is allocated the ids 11 - 20. Type/Unit : int Default : 12 Documented : Since Rel. : A.07.00 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : ECS ECA_PERLFILE Flags : external Description : Name of perl script, which should be loaded into ECS engine for managed node and should reside in AGENT_CONFIG_DIR directory. Type/Unit : string Default : empty Documented : N Since Rel. : A.08.53 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : ECS EC_MAX_AS_WAIT Flags : external Description : ECS engine waits EC_MAX_AS_WAIT seconds to connect to annotate server at startup and at reconfiguration time to avoid race condition. Type/Unit : int (seconds) Default : 10 Documented : Since Rel. : A.07.00 ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : ECS EC_MAX_ESOK_TRY Flags : external Description : Maximum number of retries attempts by ECS engine to connect to EC annotate server socket stack. Type/Unit : int Default : 20 Documented : Since Rel. : A.07.00 ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : ECS EC_SHOW_TIMESTAMP Flags : external Description : Show timestamp in ecenglg and ecengtr files Type/Unit : bool Default : FALSE Documented : Y (patch docu) Since Rel. : A.07.26 / A.08.15 Used In : opcsvinfo (<=OVO7); namespace: opc (>=OVO8) Search-Keys : EXT_INTERVAL Flags : external Description : Values of the frequency with which the monitor queue is checked if external monitors are configured. Type/Unit : int , second , > 1 Default : 15 Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : FAILED_COLLECTION_RETRIES Flags : external Description : Specifies whether startup of a failed collection should be restarted for an Advanced Monitor Policy. 0 : No retries should be done. -1 : This failure is ignored - the policy does not go into failed state (This is like it was with agents before A.07.26). Type/Unit : int Default : 3 Documented : Since Rel. : A.07.26 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : FAILED_POLICY_TIME_TO_REACTIVATE Flags : external Description : You can automatically attempt to reactivate a policy in the failed state. The time before reactivation is attempted can be specified with this variable. The time is specified in hours. Use 0, if no reactivation should be done. Type/Unit : int Default : 24 Documented : Since Rel. : A.07.26 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : IPADDR_CHECK_INTERVAL Flags : external Description : Time interval in seconds for check of IP address change (DHCP). Type/Unit : int Default : 1800 (30 minutes) Documented : Yes (HTTPS Agent Concepts and Configuration Guide) Since Rel. : A.08.00 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : LE_CONFIG_FLG_INTV Flags : external Description : Time interval between log file encapsulator checks for the existence of the configuration flag file (MPE only). Type/Unit : int , second , > 5 Default : 15 Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : MPE LIMIT_NBR_PARALLEL_ACTIONS Flags : external Description : If the value of LIMIT_NBR_PARALLEL_ACTIONS is TRUE, then action agent will honour the value specified for MAX_NBR_PARALLEL_ACTIONS. If at any point in time the number of running actions hits the value of specified for MAX_NBR_PARALLEL_ACTIONS, action agent will wait for any of those running actions to get finished to schedule the remaining actions it has to schedule. Note that you have to set a suitable value for MAX_NBR_PARALLEL_ACTIONS depending on the number and interval of policies and execction time of scripts if you are using this variable. Type/Unit : int Default : FALSE Documented : Since Rel. : A.08.51 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : MAX_RETRIES_UNTIL_POLICY_FAILED Flags : external Description : This is the number of attempt that a policy makes to collect data. This is important for usage with external program sources. If an external program has a problem, policy handling should not be stopped immediately. Therefore, external collection is stopped and restarted a number of times. This variable specifies how often the collection is started. Use 1 if no retries should be made. Type/Unit : int Default : 3 Documented : Since Rel. : A.07.26 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : MON_CONFIG_FLG_INTV Flags : external Description : Time interval between checks for the flag file by MPE monitor configuration (MPE only). Type/Unit : int second Default : 15 Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : MPE MSGSRC_WITH_POLICY_VERSION Flags : external Description : If the value of MSGSRC_WITH_POLICY_VERSION is TRUE, then policy version will be appended to MSGSRC variable. If the value of MSGSRC_WITH_POLICY_VERSION is FALSE, then policy version will not be appended to MSGSRC variable. The default value has been changed from FALSE in agent version A.08.53 to TRUE in agent version A.08.60. Type/Unit : bool Default : TRUE (since A.08.60); FALSE (A.08.53) Documented : Since Rel. : A.08.53 ObsoleteSince. : Used In : opcinfo (>=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPCMONA_ERRORMSG_ONLY_OPCERROR Flags : external Description : If set to TRUE, error messages ranging from OpC30-3400 to OpC30-3409 are not sent to the console but logged in the agent trace. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.27 / A.08.13 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_ACTION_CHARSET Flags : external Description : To let the opcacta automatically get the system charset, use OPC_ACTION_CHARSET SYSTEM To set to a specific charset , say acp1252 , use OPC_ACTION_CHARSET acp1252 With no setting the old behaviour is used (charset of OPC_NODE_CHARSET is also used for the actions). Type/Unit : string Default : OPC_NODE_CHARSET Documented : Since Rel. : A.08.51 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_ADVMON_POLICY_VERSION_CHECK Flags : external Description : If OPC_ADVMON_POLICY_VERSION_CHECK is set to TRUE, then policy version comparison will be performed before reloading the policy. The policy will be loaded only when the its policy version is higher than the currently installed policy. This config variable affects all monitor policies that access CODA data source and when management server is OM for Unix and all ADVMON policies when management server is OM for Windows. When the management server is OM for Windows, the default value of TRUE will suffice. When the management server is OM for Unix, this value should be set to FALSE otherwise any changes made to monitor policies that access CODA data source will not be reflected on the managed node. Type/Unit : boolean Default : TRUE Documented : Y Since Rel. : A.08.60 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_AGENT_ID Flags : external Description : The managed node identifier, stored on agent and server. Used to identify messages, action requests, etc. Introduced to support DHCP environments. Type/Unit : string Default : "" Documented : Since Rel. : A.07.00 ObsoleteSince. : Used In : nodeinfo (<=OVO7) Search-Keys : OPC_AGTKILL_TIMEOUT Flags : external Description : UNIX only. Time delay for a complete agent shutdown (opcagt -kill). After the set time, the agent is killed with -9 Type/Unit : int Default : 120 Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : UNIX OPC_AGTSTOP_TIMEOUT Flags : external Description : Time delay for an interceptor process to shut down. Type/Unit : int , second Default : 4 Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_AGT_PROCESS_PRIORITY Flags : external Description : Windows only Change the priority of the agent processes. This now defaults to "Below Normal" (W2K) or "IDLE" (WinNT4). Possible settings: ABOVE NORMAL BELOW IDLE NOTE: ABOVE and BELOW settings are available only on W2K. On NT 4 ABOVE is mapped to NORMAL and BELOW is mapped to IDLE. Type/Unit : string Default : BELOW Documented : Since Rel. : A.07.20 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_ALT_AGENT_IDS Flags : external Description : List of comma-separated agent_ids (no blanks). Communication from management server to agent is accepted if the management server uses one of the ALT_AGENT_IDS. Used to allow action execution on virtual cluster nodes (add agent_id of virtual node to OPC_ALT_AGENT_IDS). Supported for OVO Windows 7.0 and OVO UNIX >= 7.5. Type/Unit : string Default : "" Documented : Since Rel. : A.07.00 (OVOW); A.07.50 (OVOU) ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_COMM_LOOKUP_RPC_SRV Flags : external Description : Flag telling DCE RPC clients whether to lookup the desired RPC server in the case that no static port for this server has been found in a port configuration file. Documented in the 'DCE Communication Without Endpoint Mapper' white paper. Type/Unit : bool Default : TRUE Documented : DCE Communication Without Endpoint Mapper white paper Since Rel. : A.07.10 ObsoleteSince. : Used In : opcsvinfo, opcinfo (<=OVO7); namespace: opc, eaagt (>=OVO8) Search-Keys : OPC_COMM_PORT_DISTM Flags : external Description : Port number of Distribution Manager to be set on managed node to tell opcdista where the opcdistm is listening on the primary management server. Documented in the 'DCE Communication Without Endpoint Mapper' white paper. Type/Unit : int (port number) Default : (not set) Documented : DCE Communication Without Endpoint Mapper white paper Since Rel. : A.07.10 ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_COMM_PORT_MSGR Flags : external Description : Port number of DCE Message Receiver to be set on Managed Node to tell opcmsga where the opcmsgrd is listening on the primary management server. Documented in the 'DCE Communication Without Endpoint Mapper' white paper. Type/Unit : int (port number) Default : (not set) Documented : DCE Communication Without Endpoint Mapper white paper Since Rel. : A.07.10 ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_COMM_REGISTER_RPC_SRV Flags : external Description : Flag telling DCE RPC servers whether to register with the local rpcd. Documented in the 'DCE Communication Without Endpoint Mapper' white paper. Type/Unit : bool Default : TRUE Documented : DCE Communication Without Endpoint Mapper white paper Since Rel. : A.07.10 ObsoleteSince. : Used In : opcsvinfo, opcinfo (<=OVO7); namespace: opc, eaagt (>=OVO8) Search-Keys : OPC_COMM_RPC_PORT_FILE Flags : external Description : Full path to port configuration file needed by DCE RPC clients to determine where the required RPC servers are listening. Documented in the 'DCE Communication Without Endpoint Mapper' white paper. Type/Unit : string Default : (not set) Documented : DCE Communication Without Endpoint Mapper white paper Since Rel. : A.07.10 ObsoleteSince. : Used In : opcsvinfo, opcinfo (<=OVO7); namespace: opc, eaagt (>=OVO8) Search-Keys : OPC_DISABLE_MSGGRP_OVERRIDE Flags : external Description : If this variable is set to TRUE category/message group in message will not get replaced with that of SNMP/CMIP event recieved. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.35 / A.08.14 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_DISABLE_SEVERITY_OVERRIDE Flags : external Description : If This variable is set to TRUE severity in message will not get replaced with that of SNMP/CMIP event recieved. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.35 / A.08.14 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_DYNAMIC_LOGFILE_ONCE Flags : external Description : If this variable is set to TRUE, dynamic evaluation of logpaths in log file encapsulator is done only after startup or template distribution. Behavior as for VPO 6 and earlier. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.00 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_EVENT_RETRY_OLDEST Flags : external Description : Set the number of times that opcle attempts to read an event in case the EventLog fills up very fast. If the EventLog fills up very fast, it is possible that the last events are overwritten before opcle can process them. In order to keep up with the fill rate of the EventLog, opcle must skip the overwritten Events and starts at the current end of the EventLog. The opcle does retry this for the configured number of times. Type/Unit : integer Default : 30 Documented : N Since Rel. : A.07.28 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_EVENT_RUNTIME_ONLY Flags : external Description : Configure the Windows Event Log monitoring to limit reading events to those that arrive during agent runtime. All events that arrive during reboot or the time the agent is stopped are ignored. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.25 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_IGNORE_DEFAULT_MSG_CORRELATION Flags : external Description : If the value of OPC_IGNORE_DEFAULT_MSG_CORRELATION is TRUE, During agent converting the loaded configuration them to internal data structure, default message correlation values are not merged to the conditional correlation values. If the value of OPC_IGNORE_DEFAULT_MSG_CORRELATION is FALSE, During agent converting the loaded configuration them to internal data structure, default message correlation values are merged to the conditional correlation values. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.08.60 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_IMMEDIATE_SHUTDOWN Flags : external Description : Defines whether the Windows agent waits for the Service Control Manager to request the agent service to stop during system shutdown or whether it listens for the console message and shuts down after this is received. By default, the agent waits for the Service Control Manager. If this value is set to TRUE, it shuts down as soon as the console message of the shutdown is received. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.32 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_INCLUDE_VIRTUAL_IP_ADDRS_FOR_LOCAL_NODE_MAPPING Flags : external Description : Since OVO 8.16, the virtual addresses of HA packages is ignored when establishing whether the message node is local or not. This means: # opcmsg a=a o=o msg_t=t node= is treated as a proxied message. Before 8.16, these messages were marked as local (not-proxied), and added to the physical node when writing them to the DB. Therefore the messages were ignored for the service tree of the virtual host and the status calculation not correct. If this variable is set to TRUE, the virtual IP address is taken into account and the pre-OVO 8.16 behavior is achieved. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.08.16 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_INT_MSG_FLT_AWS Flags : external Description : With this variable set to TRUE, OVO internal messages are always filtered by the Message Interceptor, even if the process itself is not running. In this case, internal messages arrive at the next startup of the Message Interceptor. Setting this variable to TRUE, no internal messages are sent unfiltered to the Management Server. Be careful when using this setting, as OVO internal messages sent to the management server may arrive delayed. Important Note: OPC_INT_MSG_FLT must be set to TRUE in order to use OPC_INT_MSG_FLT_AWS! Type/Unit : bool Default : FALSE Documented : Y Since Rel. : A.07.26 ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : OPC_KEEP_PERL_PATH Flags : external Description : If set to TRUE, the monitor agent removes the OV perl directory from the PATH environment variable before executing a program. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.08.12 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_KILL_AUTO_ACTION_TIMEOUT Flags : external Description : Defines the timeout period that an action in the action queue must be running before the action agent assumes that it is a hanging action and kills it. (See also OPC_KILL_AUTO_ACTION) Type/Unit : int Default : 590 Documented : Y Since Rel. : A.07.21 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_KILL_SCHEDULE Flags : external Description : On Windows systems, processes started for scheduled actions from the action agent may hang. The action agent was designed to wait until the process finishes. Therefore more and more processes were started and were then blocked. The design behavior was changed to the following: When a new request to start a process for a scheduled action arrives at the action agent, it first checks whether a process already started from the same policy is still running. IF YES THEN It checks whether the process has already run longer than the configurable timeout (default 55 seconds). IF YES THEN The old process is killed. A warning is written to the opcerror log. No end or failed message is sent to the management server. The new process is started. ELSE The new process is not started. A warning is written to the opcerror log. No start message is sent to the management server. ENDIF ELSE The new process is started. ENDIF OPC_KILL_SCHEDULE can be used to disable the new functionality. If this variable is set to FALSE the action agent behaves as originally designed. Type/Unit : boolean Default : TRUE Documented : Y Since Rel. : A.07.22 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_KILL_SCHEDULE_TIMEOUT Flags : external Description : Defines the timeout period that is used to check whether an old process is killed or the new one not started. (See also OPC_KILL_SCHEDULE) It can be set to 0 Default of 55 seconds is used. >0 Number is used as the timeout period in seconds. <0 No timeout check is done, the old process is killed immediately. Type/Unit : int Default : 55 Documented : Y Since Rel. : A.07.22 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_LE_CALC_HASH Flags : external Description : If the value of OPC_LE_CALC_HASH is TRUE, opcle detects the file is appended or overwritten by calculating hash of last line and verifying some random check points.If opcle detects the file is overwritten, then it reads the file from beginning. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.08.60 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_LE_CHECK_INODE Flags : external Description : Sets the time interval when a file name change is recognized by the log file encapsulator. Type/Unit : int Default : 20 Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_LE_CLOSE_MSG_DLL Flags : external Description : If this variable is set to TRUE, the Windows message DLL for EventLog messages is closed after every read. This may cause a higher CPU usage by the log file encapsulator process but it does not lock DLLs and so software may be updated while the OVO agent runs. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : NT OPC_LE_IGN_TEMP_UNAVAIL Flags : external Description : If set to TRUE, temporarly unavailable logfiles will not be treated as recreated/truncated logfiles. The information about the file position will be saved during the file is unavailable. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_LE_SAVE_STATE Flags : external Description : With this flag opcle now save the information about the files it was monitoring into the file /var/opt/OV/tmp/OpC/le_state. When opcle comes up and if this file is existing then it will restore the last saved information. By this we can now monitor the messages that were written into the file opcle was monitoring even when it was down. Note : opcle will consider the file le_state as obsolete if it is older than a 24hr. Type/Unit : boolean Default : FALSE Documented : Y Since Rel. : A.07.32, 8.15 Used In : opcinfo (<=OVO7); namespace: opc (>=OVO8) Search-Keys : OPC_LE_KEEP_DSCONNECTION Flags Description Type/Unit Default : external : In windows platform opcle locks port 1025 and 1026 towards the PDC emulator(primary domain controller). If set to TRUE the connection kept as long as opcle is running. If set to FALSE connection is closed after each request to unlock the port. : bool : FALSE Documented : Since Rel. : A.07.33/A.08.14.1 ObsoleteSince. : Used In : opcinfo/nodeinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_LE_MAX_LINES_READ Flags : external Description : Determines how many lines the log file encapsulator reads per specified time period. A value of 0 means that there is no limit. Type/Unit : int Default : 50 Documented : Since Rel. : A.07.22 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_MAX_ERROR_HANDLING Flags : external Description : If set to TRUE, errors are always sent as an OVO message to the management server and are also logged in opcerror. Note: Only opcmon command uses this feature. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_MGMTSV_CHARSET Flags : external Description : Character Set of OVO management server. Values: roman8,iso88591,ebcdic,sjis,euc,ASCII Type/Unit : string Default : iso88591 Documented : Since Rel. : ObsoleteSince. : Used In : nodeinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : OPC_MONA_MSG_PER_STATE Flags : external Description : If set to TRUE, a message is sent each time a state/threshold is reached rather than just the first time. This applies only to Advanced Monitoring in opcmona. Type/Unit : bool Default : TRUE Documented : Since Rel. : A.07.23 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_MSGA_ITO6_COMPAT_MODE Flags : external Description : Forces opcmsga to send the message in VPO 6 format so that it can read by a VPO 6 Message Receiver. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.25 ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_MSGA_PING_SERVER_INTERVAL Flags : external Description : interval in which unreached OVO 8 servers are BBC-ping-ed. Type/Unit : int; # of seconds Default : 60 Documented : Since Rel. : A.08.16 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_MSG_FLT_EXCLUDE_SVC Flags : external Description : If set to TRUE, OVO-internal messages do not carry over Service Name field from original message. The Service Name is then an empty value. This is the behavior that existed before the fix for defect QXCR1000321305 was implemented. Type/Unit : bool Default : FALSE Documented : Y Since Rel. : A.07.27; A.08.25 ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : OPC_NAMESRV_BUFFER_SIZE Flags : external Description : Provides initial value for the buffer size to get host data from IP address,if buffer size is insufficient then it is incremented repeatedly by the provided value untill host data is retrieved successfully. Type/Unit : int Default : 512 Documented : Since Rel. : A.07.28 / A.08.11 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_NEW_LOGFILE_FROM_BEGIN Flags : external Description : If set to TRUE, the log file encapsulator reads newly discovered log files from the beginning. "Newly discovered" means that a script is used to dynamically list the log files to be monitored and this log file template has already run once. If set to FALSE (default), such newly discovered log files are read from the last file position (if so configured). Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.20 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_NODE_CHARSET Flags : external Description : Character set of managed node. Can be set in OVO Admin GUI. Values: roman8,iso88591,ebcdic,sjis,euc,ASCII Should NOT change this setting on the node itself using ovconfchg -ns eaagt -set Type/Unit : string Default : roman8 Documented : Since Rel. : ObsoleteSince. : Used In : nodeinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_NO_CFG_RQST_AT_STARTUP Flags : external Description : Do not ask the OVO server for new configuration at agent startup. This works only for following combinations: - All agents in OVO for Windows environment. - Only Windows agent in ITO/OVO for UNIX environment. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_NO_MSG_FLT_FOR_BUFFER_MSG Flags : external Description : When internal message filtering is enabled, by default, all internal messages are passed on to the message interceptor. If this flag is set to TRUE, messages relating to the message agent's buffering (OpC40-1410 and OpC40-1411) are excluded and they are forwarded to the GUI/DB directly. This avoids the situation that these messages are also buffered. Type/Unit : boolean Default : FALSE Documented : Since Rel. : A.07.23 ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : OPC_OPCLE_POLICY_EXCLUDE_INFO Flags : external Description : Comma-separated list of policy-name prefixes. All policies, with names that begin with such prefixes, are not processed by the normal opcle. Example: "abc,bcd" -> policies "abcd 500" and "bcde 600" are not processed. This variable is only useful in conjunction with the "multiple parallel opcle" feature. Type/Unit : string; comma-separated list, no blanks in between Default : Documented : Since Rel. : A.08.13 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_OPCMSG_API_CHECK_MSGI_RUNNING Flags : external Description : If set to TRUE, opcmsg() and opcagtmsg_send() will not write message to queue if message interceptor is not running and the APIs will return an error. Type/Unit : bool Default : FALSE Documented : Since Rel. : > A.08.17 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_OPCMSG_CLI_CHECK_MSGI_RUNNING Flags : external Description : If set to FALSE, opcmsg CLI will write the message to queue even if message interceptor is not running. Type/Unit : bool Default : TRUE Documented : Since Rel. : > A.08.17 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_PERL_INCLUDE_INSTR_DIR Flags : external Description : If set to TRUE, perl modules available in the instrumentation directory will be made available for embedded perl policies processed by the monitor agent. The default value has been changed from FALSE in agent version A.08.53 to TRUE in agent version A.08.60. Type/Unit : boolean Default : TRUE (since A.08.60); FALSE (A.08.53) Documented : Since Rel. : A.08.6 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_PERL_SERIALIZE Flags : external Description : If set to TRUE, the monitor agent serializes the execution of embedded perl scripts used within advanced monitoring policies instead of parallel execution. Type/Unit : bool Default : FALSE Documented : Since Rel. : > A.07.35 ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_PRIMARY_MGR Flags : external Description : Define primary manager for messages. Corresponds to mgrconf policy. Example: [eaagt] OPC_MGMT_SERVER=servername.bbn.hp.com Type/Unit : string Default : Documented : Since Rel. : A.08.00 ObsoleteSince. : Used In : namespace: eaagt (>=OVO8) Search-Keys : OPC_PROC_ALWAYS_INTERACTIVE Flags : external Description : This switch tells the agent how to start processes on Windows nodes. This is helpful due to a problem in Windows 2000, where processes may hang when they are started with access to the default desktop as long as there is no user logged on. This is documented in: http://support.microsoft.com/?id=821107 To avoid this problem without installing the mentioned hotfix, you can set this variable to FALSE. But this may result in problems executing tools that require a switch user. Those tools may just fail without any output. In case you do not run tools that require a switch user, you can safely set this option to FALSE. Otherwise, install the hotfix provided by Microsoft. Type/Unit : bool Default : TRUE Documented : Since Rel. : A.07.23; A.08.10 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_Q_SYNC_WRITES Flags : external Description : If set to TRUE, updates to the queue are synchronized to the disk at critical places. This drastically reduces queue performance, but further reduces the chance of corrupted queue files. It's best to limit this parameter to opcmsgm. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.23 ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : OPC_RESOLVE_TRAP_LOCALHOST Flags : external Description : If set to TRUE, the trap/event interceptor replaces the source address 127.0.0.1 in a trap with the agent IP address. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.15 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_RESTART_MINIMUM_RUN_TIME Flags : external Description : Defines the time period that a sub agent process should run without being restarted more than specified by OPC_RESTART_COUNT. The time is specified in minutes. Type/Unit : integer (minutes) Default : 60 Documented : Since Rel. : A.07.15 ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_RESTART_SUBAGENT Flags : external Description : If set to TRUE, the control agent tries to restart aborted sub agent processes. The restart is done a defined number of times (OPC_RESTART_COUNT) in a specified period of time (OPC_RESTART_MINIMUM_RUN_TIME). In case the process aborts more often, it wont be restarted again. Type/Unit : TRUE|FALSE Default : TRUE Documented : Since Rel. : A.07.15 ObsoleteSince. : Used In : opcinfo (<=OVO7) Search-Keys : OPC_RPCREG_TIMEOUT Flags : external Description : Timeout for 'opcagt -status' when trying to get agent status. Type/Unit : int , second Default : 60 Documented : Since Rel. : ObsoleteSince. : A.08.00 Used In : opcinfo (<=OVO7) Search-Keys : OPC_RPC_SHORT_TIMEOUT Flags : external Description : Specifies the communication timeout "local" for RPCs (called and executed on the same machine). LOCAL_ONLY - sets timeout to 5s ALWAYS - sets timeout to 5s for local and remote NEVER - sets timeout to 30s Type/Unit : string Default : LOCAL_ONLY Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: eaagt, opc (>=OVO8) Search-Keys : OPC_SC Flags : external Description : Flag whether ITO runs on a Sun-cluster system Is set during installation by postinstall script. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcsvinfo opcinfo (<=OVO7); namespace: opc (>=OVO8) Search-Keys : OPC_SEND_MAX_ONE_MSG_PER_TRAP Flags : external Description : Can switch off processing of additional trap templates, if a message was already generated from a template. This speeds up processing, but may prevent some templates from even 'looking' at the trap. As a result, less messages might be sent to the server and the behavior of duplicate suppression for 'Suppress Messages Matching Condition' may change. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.23 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_SET_PROXY_FLAG_FOR_IP_ADDRESSES Flags : external Description : Specify a list of local IP addresses that are not replaced by the node name as known on the server, when sending messages. This is useful for agents of OVO/W. When messages are sent with a sender address of this list, the is_proxied flag of the message is set, as if the message was sent for a different node, even if that address is local (currently). You should never include the OPC_IP_ADDRESS in this list. Example: 15.139.90.118,15.139.90.119,15.139.90.120 Type/Unit : string (comma separated list of IP addresses Default : "" Documented : Since Rel. : A.07.24, A.08.16 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_SUPPRESS_ERROR_LIST Flags : external Description : A comma-separated list of - values to suppress error messages (OpC-) output to all error message output targets. Set the setting on a by process basis as some binaries may output the same error message on error condition and suppressing the message would alter the normal output. Do not insert any whitespaces. Example to suppress error messages OpC50-10 and OpC50-202 for opcmsgm process: ovconfchg -ovrg server -ns opc.opcmsgm \ -set OPC_SUPPRESS_ERROR_LIST \ "50-10,50-202" Type/Unit : string Default : Documented : Y (Patch text) Since Rel. : A.08.30 ObsoleteSince. : Used In : namespace: eaagt, opc (>=OVO8) Search-Keys : error message suppression OPC_TEMPL_STATUS Flags : external Description : Log file encapsulator and monitor agent maintain the files le.status and monitor.status in the tmp directory of the managed node. These files contain the current (internal) status of their sources if this variable is set to TRUE. Type/Unit : bool Default : FALSE Documented : N Since Rel. : A.07.22 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_TRACE_CHILD Flags : external Description : Flag whether tracing will be enabled between fork and exec for the child process (enabling can lead to mutex deadlock on multiprocessor machines) Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo, opcsvinfo (<=OVO7); namespace: opc (>=OVO8) Search-Keys : OPC_TRAP_CHARSET Flags : external Description : Character set of incoming snmp traps. If possible, this character set is converted to OPC_NODE_CHARSET. If this flag is not set, the character is not converted. NOTE: Only available on Windows nodes. Type/Unit : string Default : Documented : NSMbb63276 Since Rel. : A.07.25 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_TRUNCATE_ORIG_TEXT Flags Description : external : Truncate the original message text to the configured length. -1 : No truncation done (Default) 0 : No original message sent at all : Truncation done after the nth character Type/Unit : integer Default : -1 Documented : JAGae61807 Since Rel. : A.07.22 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_USE_PROTECTTOLS Flags : external Description : The HP ProtectTools offer enhanced security features on Windows. One of them is password tagging, salting, and preprocessing. If these tools are active, the agent needs to preprocess passwords to be able to perform a switch user. If this flag is set to TRUE, the agent tries to perform such preprocessing. Type/Unit : bool Default : FALSE Documented : Since Rel. : A.07.28 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_USE_UDP_AS_TRAP_SOURCE Flags : external Description : Set this variable to TRUE to match the pmd's -u option. The agent_addr (source of the trap) is then overwritten by the UDP packet header's source IP address. Works only when pmd is running with -u. Type/Unit : bool Default : FALSE Documented : NSMbb45184 Since Rel. : A.06.11; A.07.11 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_VC Flags : external Description : Flag whether ITO runs on a Veritas-cluster system Is set during installation by postinstall script. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcsvinfo opcinfo (<=OVO7); namespace: opc (>=OVO8) Search-Keys : OPC_WBEMI_BUF_SIZE Flags : external Description : MESSAGE OpC30-344: Policy '...': Buffer overflow. Some objects cannot be checked against the rules of the policy. Maximum size of buffer is ... INSTRUCTION: The WMI/WBEM interceptor uses an internal queue to buffer incoming objects until they can be checked. The default size of this queue is 10000 objects but this size can be changed by configuring the OPC_WBEMI_BUF_SIZE variable in the opcinfo file. If a lot of objects are received, the configured buffer size is insufficient. In this case, the oldest objects are deleted from the queue and not handled. There are some possibilities to avoid such an buffer overflow: - check why so many objects arrive. Perhaps it is possible to avoid the creation of the objects. - check whether it is possible to limit the number of objects the WMI/WBEM interceptor has to handle by using a "global WQL filter" for the policy. WMI sends only the objects matching the filter to the WMI/WBEM interceptor. - check whether it is possible to use rules to suppress objects Type/Unit : Default : Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : OPC_WIN_DONT_USE_PATH_NWDRIVE Flags : external Description : Force the Windows agent to scan the currently used environment PATH and remove all mapped network drives referenced in the PATH to avoid login errors on the machines providing the network shares. Note: This also removes relative PATH entries such as "." or ".." . Type/Unit : BOOLEAN (TRUE|FALSE) Default : FALSE Documented : Since Rel. : A.07.20 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : POLICY_MIN_INTERVALS_WAIT Flags : external Description : Minimum number of wait intervals before stopping a policy if it does not receive any data. Important for program sources where the execution time of an external program depends on the current system performance. If the system is very busy, it is possible that the execution takes longer than the configured interval. Reconfiguring the time interval that the monitor agent waits for the external programs to finish can be helpful. Use -1 if POLICY_MIN_TIME_WAIT should be used. Use 0 if the policy should not wait. Type/Unit : int Default : -1 Documented : Since Rel. : A.07.26 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_COMMUNITY Flags : external Description : Standard SNMP community to be used in trap interception. Type/Unit : string Default : public Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_REFUSE_FORWD Flags : external Description : Specifies whether the trap interceptor accepts events forwarded from another, non-local, PMD. Type/Unit : bool Default : FALSE Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_REMOTE_PMD Flags : external Description : Host where the trap interceptor tries to connect an OV PMD. Type/Unit : string , any host name Default : "" (local host) Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_REMOTE_PORT Flags : external Description : Port number to which opcmona connects when monitoring SNMP variables. Type/Unit : integer, values: > 0 Default : 161 Documented : QXCM1000191534/QXCR1000193250 Since Rel. : A.07.27 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_SESSION_MODE Flags : external Description : Mode in which the trap interceptor opens a session. Value NNM_LIBS can only be used with Windows to support SNMP V2 traps (NNM libraries are used in this case). Type/Unit : string , values: TRY_BOTH,NO_TRAPD,NNM_LIBS Default : "" (connect local trapd) Documented : Since Rel. : ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_SESSION_TRY_FOREVER Flags : external Description : If this variable set to TRUE trap interceptor process will try to connect pmd every 300 second until connection is established. Type/Unit : bool Default : FALSE Documented : Since Rel. : > A.08.17 / A.07.35 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : SNMP_TRAP_PORT Flags : external Description : Port number on which opctrapi listens when not using NNM (pmd). Type/Unit : integer, values: > 0 Default : 162 Documented : NSMbb46017 Since Rel. : A.06.12; A.07.11 ObsoleteSince. : Used In : opcinfo (<=OVO7); namespace: eaagt (>=OVO8) Search-Keys : |
HPOM, OVO, NNMI, Sitescope, Nagios y scripts, consejos y pequeñas guías para herramientas de monitorización.
jueves, 8 de noviembre de 2012
[OvO]ovconfget / ovconfchg - Variables y Parámteros
Suscribirse a:
Enviar comentarios (Atom)
No hay comentarios:
Publicar un comentario